Login
     
  
     
SPE method development kits

If you do not know the behaviour of your samples or analyte in solid phase extraction, or if you want to optimise an existing extraction procedure, we recommend MACHEREY-NAGEL method development kits. Consisting of a variety of different SPE phases and column formats they are the ideal tool for approaching any analytical task systematically.

For the development kits as well as for all individual CHROMABOND®, CHROMABOND® LV and CHROMAFIX® types columns are sealed in units of five columns each to prevent adsorption of contaminants from the environment, e.g. laboratory air.
CHROMABOND® development kits are specially conceived for different application fields and tasks: 
• the best separation mechanism for a clean-up procedure 
• the optimum polymeric phase for a clean-up procedure (HR-X, HR-P, ion exchangers, …)
• the optimum RP phase for a clean-up procedure (C18, C18ec, C8, …)
• the optimum polar phase for a clean-up procedure (SiOH, NH2, ….)
• the optimum ion exchanger for a clean-up procedure (weak or strong exchanger)
• for clean-up procedures for environmental samples (PAH, pesticides, …)



Designation Contents of the kit REF
Investigating the best separation mechanism for a clean-up procedure
CHROMABOND HR-Xpert
development kit I
columns with 3 ml / 60 mg each: 10 columns with HR-X,
5 columns each with HR-XC, HR-XA, HR-XCW, HR-XAW
730723
CHROMABOND HR-Xpert
development kit II
columns with 3 ml / 200 mg each: 10 columns with HR-X,
5 columns each with HR-XC, HR-XA, HR-XCW, HR-XAW
730726
CHROMABOND
polymer development kit
5 columns each with 3 ml / 200 mg:
HR-X, HR-XC (MCX), HR-XA (MAX), HR-P, Easy, PS-H+, PS-OH
730288
CHROMABOND
standard development kit
5 columns each with 3 ml / 500 mg:
C18, C18 ec, C8, C6H5, NH2, DMA, OH, CN, SiOH, SA (SCX), SB (SAX)
730496
Selecting the optimum RP phase for a clean-up procedure
CHROMABOND
RP development kit I
10 columns each with 3 ml / 500 mg: C18, C18 ec, C8, C4
and 10 columns each with 3 ml / 200 mg HR-P, HR-X
730197
CHROMABOND
RP development kit II
10 columns each with 1 ml / 100 mg:
C18, C18 ec, C8, C4, HR-P, HR-X
730207
CHROMAFIX
RP development kit I
10 cartridges each CHROMAFIX S:
C18, C18 ec, C8, C4, HR-P, HR-X
731883
     
CHROMABOND
RP development kit III
10 columns each with 3 ml / 500 mg: C18, C18 ec, C18 Hydra, C8
and 10 columns each with 3 ml / 200 mg HR-P, HR-X
730490
CHROMABOND
RP development kit IV
10 columns each with 1 ml / 100 mg:
C18, C18 ec, C18 Hydra, C8, HR-P, HR-X
730491
CHROMAFIX
RP development kit II
10 cartridges each CHROMAFIX S:
C18, C18 ec, C18 Hydra, C8, HR-P, HR-X
731886
     
CHROMABOND
RP development kit V
10 columns each with 3 ml / 500 mg:
C6H5, NO2, C6H11 ec, C4, C2
730492
CHROMABOND
RP development kit VI
10 columns each with 1 ml / 100 mg:
C6H5, NO2, C6H11 ec, C4, C2
730493
CHROMAFIX
RP development kit III
10 cartridges each CHROMAFIX S:
C6H5, NO2, C6H11 ec, C4, C2
731887
Selecting the optimum polar phase for a clean-up procedure
CHROMABOND
polar development kit I
10 columns each with 3 ml / 500 mg:
SiOH, Florisil®, NH2, CN, OH
730199
CHROMABOND
polar development kit II
10 columns each with 1 ml / 100 mg:
SiOH, Florisil®, NH2, CN, OH
730208
CHROMAFIX
polar development kit I
10 cartridges each CHROMAFIX S:
SiOH, Florisil®, NH2, CN, OH
731884
Selecting the optimum ion exchanger for a clean-up procedure
CHROMABOND ion exchange
development kit I
10 columns each with 3 ml / 500 mg:
SA (SCX), SB (SAX), HR-XC (MCX), HR-XA (MAX), PS-OH, PS-H+, DMA
730206
CHROMABOND ion exchange
development kit II
10 columns each with 1 ml / 100 mg:
SA (SCX), SB (SAX), HR-XC (MCX), HR-XA (MAX), PS-OH, PS-H+, DMA
730209
CHROMAFIX ion exchange
development kit I
10 cartridges each CHROMAFIX S:
SA (SCX), SB (SAX), HR-XC (MCX), HR-XA (MAX), PS-OH, PS-H+, DMA
731885
     
CHROMABOND cation exchange
development kit I
10 columns each with 3 ml / 500 mg:
SA (SCX), PSA, PCA, HR-XC (MCX), HR-XCW (WCX), PS-H+
730494
CHROMAFIX cation exchange
development kit
10 cartridges each CHROMAFIX S:
SA (SCX), PSA, PCA, HR-XC (MCX), HR-XCW (WCX), PS-H+
731888
Phase selection for clean-up procedures for environmental samples
CHROMABOND kit I for
environmental
sample preparation
10 columns each with 3 ml / 200 mg HR-P, 6 ml / 1000 mg C18 ec,
6 ml / 2000 mg C18 PAH, 6 ml / 500/1000 mg CN/SiOH,
3 ml / 500/500 mg SA/SiOH
730205
CHROMABOND kit II for
environmental
sample preparation
5 columns each with 3 ml / 500/500 mg SiOH-H2SO4/SA,
3 ml / 500 mg SiOH, 6 ml / 1000 mg Florisil,
3 ml / 500/500 mg SA/SiOH, 6 ml / 700/2000/700 mg NAN
730349
Columns are sealed in units of five columns each.

 Print   
   
  