This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
"Allow all cookies" cookie
"Decline all cookies" cookie
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Individual prices
Region preferences
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
VA HPLC column (analytical), PS/DVB Polymer, NUCLEOGEL GPC, 10 µm, 300x7,7 mm
$2,825.00 * $0.00 * (0% Saved)
*taxes and shipping not included
Delivery time approx. 5 working days
Item number: 719414 024040300010
Package unit 1 Column(s) Do you have any questions?
Please contact us. Polymer-based columns for size exclusion chromatography (SEC) or gel permeation chromatography... more
Polymer-based columns for size exclusion chromatography (SEC) or gel permeation chromatography (GPC) of water-insoluble substances. Highly crosslinked macroporous, spherical polystyrene – divinylbenzene polymer matrix with good mechanical stability.
Method | Special analytical HPLC |
Brand | NUCLEOGEL |
Base material | Spherical polystyrene – divinylbenzene polymer matrix |
Phase | NUCLEOGEL GPC |
USP listing | Not available or not applicable |
Surface chemistry | Highly crosslinked macroporous, spherical polystyrene – divinylbenzene polymer (PS/DVB) |
Mode | Size exclusion chromatography (SEC) / Gel permeation chromatography (GPC) |
Type | VA HPLC column (analytical) |
Hardware | Stainless steel |
Column length | 300 mm |
Column inner diameter | 7.7 mm |
Particle type | Fully porous particles (FPP), Macroporous |
Particle shape | Spherical |
Particle size | 10 µm |
Eluent in HPLC column | Toluene |
Recommended application(s) | Gel permeation chromatography (GPC), GPC clean-up of samples without water content, Only for water-insoluble substances, Size exclusion chromatography (SEC) |
Exclusion limit | 500 kDa |
Endcapped | No |
Carbon content | Not available or not applicable |
pH stability | Not available or not applicable |
Pore size | 50 Å |
Specific surface according to BET | 420 m²/g |
Temperature stability (max) | 150 °C |
Pressure stability (max) | 150 bar / 2175 psi |
Column volume | 14 mL |
Storage temperature | 15–25 °C / 59–77 °F |
Scope of delivery | 1x analytical HPLC column, instruction leaflet, certificate of analysis |
Gross weight (incl. packaging) | 312.77 g / 0.69 lbs |
Packaging dimensions | 405 x 117 x 54 mm / 15.94 x 4.61 x 2.13 Inch |
Hazardous material | No |
VA HPLC column (analytical), PS/DVB Polymer, NUCLEOGEL GPC, 5 µm, 300x7,7 mm
Content 1 Column(s)
REF 719402
$
VA HPLC column (analytical), PS/DVB Polymer, NUCLEOGEL GPC, 5 µm, 300x7,7 mm
Content 1 Column(s)
REF 719403
$
VA HPLC column (analytical), PS/DVB Polymer, NUCLEOGEL GPC, 5 µm, 300x7,7 mm
Content 1 Column(s)
REF 719404
$
VA HPLC column (analytical), PS/DVB Polymer, NUCLEOGEL GPC, 5 µm, 300x7,7 mm
Content 1 Column(s)
REF 719405
$
VA HPLC column (analytical), PS/DVB Polymer, NUCLEOGEL GPC, 5 µm, 300x7,7 mm
Content 1 Column(s)
REF 719406
$
VA HPLC column (analytical), PS/DVB Polymer, NUCLEOGEL GPC, 10 µm, 300x7,7 mm
Content 1 Column(s)
REF 719410
$
VA HPLC column (analytical), PS/DVB Polymer, NUCLEOGEL GPC, 10 µm, 300x7,7 mm
Content 1 Column(s)
REF 719411
$
VA HPLC column (analytical), PS/DVB Polymer, NUCLEOGEL GPC, 10 µm, 300x7,7 mm
Content 1 Column(s)
REF 719412
$
VA HPLC column (analytical), PS/DVB Polymer, NUCLEOGEL GPC, 10 µm, 300x7,7 mm
Content 1 Column(s)
REF 719413
$
HPLC guard column, analytical, PS/DVB polymer, NUCLEOGEL GPC, 50x7.7 mm, 10 µm
Content 1 Column(s)
REF 719418
$